Start practice — 8 questions →
Sample questions
Which of the following is a specific restriction regarding mixing Premise 75 WP?
- Do not use with products or in a tank that may contain boron or release free chlorine
- Do not mix with water temperatures below 50 degrees
- Do not mix with any other liquid termiticide
- Do not use in tanks made of plastic
Show answer
The label explicitly prohibits use with products or in tanks that may contain boron or release free chlorine.According to the label, when should a 0.1% dilution be used instead of a 0.05% dilution?
- Where severe or persistent infestations occur
- When applying to concrete slabs
- When using cooler water temperatures
- When applying to hollow masonry units
Show answer
The label states a 0.1% dilution may be used where severe or persistent infestations occur.When applying to voids in hollow masonry units, what is the required rate?
- 2 gallons per 10 linear feet of wall
- 1 gallon per 10 square feet
- 4 gallons per 10 linear feet
- 1.5 gallons per 10 square feet
Show answer
The label specifies a rate of 2 gallons per 10 linear feet of wall for voids in hollow masonry units.If soil conditions will not accept the standard 4 gallons per 10 linear feet, what alternative application method is permitted?
- Apply 2 gallons of solution at a 0.1% concentration per 10 linear feet
- Apply 8 gallons of solution at a 0.05% concentration per 10 linear feet
- Apply 2 gallons of solution at a 0.05% concentration per 10 linear feet
- Apply 4 gallons of solution at a 0.2% concentration per 10 linear feet
Show answer
The label allows applying twice the concentration in 2 gallons of solution per 10 linear feet if soil won't accept 4 gallons.What is the primary target pest for Premise 75 WP Termiticide according to the label?
- Subterranean termite
- Carpenter ant
- Termite larvae only
- All wood-destroying insects
Show answer
The label specifically lists subterranean termite as the target pest.What effect does cooler water temperature have during the mixing process?
- It increases the time needed for the inner packet to dissolve completely
- It prevents the dilution from reaching 0.1%
- It requires a higher concentration of product
- It makes the solution more effective for soil penetration
Show answer
The label notes that cooler water temperatures increase the time needed for the inner packet to dissolve.Where is Premise 75 WP Termiticide intended to be applied?
- Outdoor
- Indoor
- Both Indoor and Outdoor
- Greenhouse only
Show answer
All listed application sites and locations in the provided facts are categorized as Outdoor.When treating typical control situations for subterranean termites in soil, what dilution should generally be used?
Show answer
The label states that generally a 0.05% dilution is used for typical control situations.
← All practice exams