Start practice — 8 questions →
Sample questions
When treating grain storage facilities for listed Granary Insects, how much spray mix should be used per 1000 sq. ft. of surface area?
- One gallon of spray mix
- Two gallons of spray mix
- Half a gallon of spray mix
- Five gallons of spray mix
Show answer
The label instructs to apply using one gallon of spray mix per 1000 sq. ft. of surface area to be treated for granary insects.🔗 Source
For an indoor light infestation of Spiders and other listed Crawling Insects, what is the mixing rate per gallon?
- 2.0 fl. oz. / gallon
- 1.5 fl. oz. / gallon
- 0.5 fl. oz. / gallon
- 5.0 fl. oz. / gallon
Show answer
The mixing instructions specify 0.5 fl. oz. / gallon for Spiders and other listed Crawling Insects (Light Infestation) indoors.🔗 Source
When applying the product to livestock and poultry premises for crawling insects, where should you NOT apply the product?
- In vertical surfaces
- In cracks and crevices
- In feeders
- Under feeders
Show answer
The label specifies to treat areas including under (but not in) feeders.🔗 Source
Where should ants be treated according to the indoor application instructions?
- Only in attics and crawl spaces
- Ant trails, around garbage receptacles, and near food sources
- Only inside floor drains and non-food conveyors
- Exclusively on exterior foundation walls
Show answer
For ants, the label says to apply to ant trails, around garbage receptacles, and near food sources, as well as around doors and windows.🔗 Source
Which of the following is a specific restriction regarding tank mixing this product?
- Do not tank mix with products containing organophosphates
- Do not tank mix with products containing dichlorvos (DDVP)
- Do not tank mix with any liquid fertilizers
- Do not tank mix with products containing pyrethroids
Show answer
The restrictions state: Do not tank mix Onslaught FastCap Spider & Scorpion Insecticide with products containing dichlorvos (DDVP).🔗 Source
According to the timing and weather instructions, what is the maximum frequency for repeat applications?
- Do not exceed more than one application every seven (7) days
- Do not exceed more than one application every twenty-one (21) days
- Do not exceed more than one application every fourteen (14) days
- Do not exceed more than one application every forty-eight (48) hours
Show answer
The timing instructions state: Repeat application as needed, but do not exceed more than one application every fourteen (14) days.🔗 Source
Which of these is a listed target pest for this product?
- Litter beetles (darkling, hide, and carrion beetles)
- Termites
- Cockroaches
- Bed bugs
Show answer
Litter beetles (darkling, hide, and carrion beetles) are explicitly listed as a target pest.🔗 Source
When treating livestock and poultry premises for Litter beetles, what is the recommended perimeter treatment width for the exterior foundation wall?
- 1 to 3 feet up the wall and 3 to 6 feet out from the foundation
- 3 to 6 feet up the wall and 1 to 3 feet out from the foundation
- 5 feet up the wall and 5 feet out from the foundation
- 1 foot up the wall and 1 foot out from the foundation
Show answer
The label states to apply a uniform band 1 to 3 feet up the exterior foundation wall and 3 to 6 feet out from the foundation to reduce immigration.🔗 Source
← All practice exams