HP II High Precision Injection System archived Termidor HP II High Precision Te 2026 03 22

HP II High Precision Injection System archived Termidor HP II High Precision Te 2026 03 22 — 8 practice exam questions with instant feedback and cited explanations.

Practice ExamsChemicals › HP II High Precision Injection System archived Termidor HP II High Precision Te 2026 03 22
Start practice — 8 questions →

Sample questions

When treating a sump pump pit, what must a technician do if the water level rises after removing four cups of water and waiting 10 minutes?

Show answer If the water level rises after the 10-minute check, the label states there is too much seepage to perform the treatment at that time.

🔗 Source

When performing interior Plenum Construction treatment, what must be done with the sealing fabric?

Show answer The label states to ensure the sealing fabric is removed to expose no more than 18 inches adjacent to all foundation structures.

🔗 Source

When treating horizontal treated zones (soil surface) outdoors, what is the required application rate per 10 square feet?

Show answer The label specifies a rate of 1.0 to 1.5 gallons per 10 square feet for horizontal treated zones at the soil surface.

🔗 Source

When applying Termidor H•P II finished dilution in SA-Mode, what is the restriction regarding wells or cisterns?

Show answer The label states: 'DO NOT apply Termidor H•P II finished dilution within 10 feet of any well or cistern when using SA-Mode.'

🔗 Source

When drilling through a foundation wall to treat soil adjacent to the foundation, what is the maximum allowable distance between drill holes?

Show answer The label instructs to drill (no wider than 18 inches apart) through the foundation wall or through the floor.

🔗 Source

According to the label, which application method is strictly prohibited for this product?

Show answer The label explicitly states: 'DO NOT broadcast or power spray with high pressure.'

🔗 Source

When using the Backfill Method (trench) outdoors, what is the required application rate?

Show answer The label states the rate for the Backfill Method is 2 gallons per 10 linear feet per foot of depth of the trench.

🔗 Source

Regarding air circulation systems, when should any system that moves air from the treated area to an untreated interior space be turned off?

Show answer The label requires turning off air circulation systems until application is completed and all finished dilution has been absorbed by the soil.

🔗 Source

← All practice exams