Practice Exams ›
Chemicals › HP II High Precision Injection System archived Termidor HP II High Precision Te 2026 03 22
Start practice — 8 questions →
Sample questions
When treating a sump pump pit, what must a technician do if the water level rises after removing four cups of water and waiting 10 minutes?
- Proceed with treatment but keep the pump unplugged
- Add more Termidor H•P II finished dilution to the pit
- Stop the treatment because there is too much seepage
- Plug the pump in immediately to stabilize the level
Show answer
If the water level rises after the 10-minute check, the label states there is too much seepage to perform the treatment at that time.🔗 Source
When performing interior Plenum Construction treatment, what must be done with the sealing fabric?
- It must be applied over the soil before treatment
- It must be removed to expose no more than 18 inches adjacent to foundation structures
- It must be soaked in Termidor H•P II finished dilution
- It must be replaced immediately before the soil absorbs the liquid
Show answer
The label states to ensure the sealing fabric is removed to expose no more than 18 inches adjacent to all foundation structures.🔗 Source
When treating horizontal treated zones (soil surface) outdoors, what is the required application rate per 10 square feet?
- 1.0 to 1.5 gallons of Termidor H•P II finished dilution
- 2.0 gallons of Termidor H•P II finished dilution
- 0.5 to 1.0 gallons of Termidor H•P II finished dilution
- 1.0 gallon per cubic foot of soil
Show answer
The label specifies a rate of 1.0 to 1.5 gallons per 10 square feet for horizontal treated zones at the soil surface.🔗 Source
When applying Termidor H•P II finished dilution in SA-Mode, what is the restriction regarding wells or cisterns?
- Do not apply within 5 feet of any well or cistern
- Do not apply within 10 feet of any well or cistern
- Do not apply within 15 feet of any well or cistern
- Do not apply within 20 feet of any well or cistern
Show answer
The label states: 'DO NOT apply Termidor H•P II finished dilution within 10 feet of any well or cistern when using SA-Mode.'🔗 Source
When drilling through a foundation wall to treat soil adjacent to the foundation, what is the maximum allowable distance between drill holes?
- 6 inches
- 10 inches
- 12 inches
- 18 inches
Show answer
The label instructs to drill (no wider than 18 inches apart) through the foundation wall or through the floor.🔗 Source
According to the label, which application method is strictly prohibited for this product?
- Short-rodding techniques
- Long-rodding techniques
- Broadcasting or power spraying with high pressure
- Backfill Method in trenches
Show answer
The label explicitly states: 'DO NOT broadcast or power spray with high pressure.'🔗 Source
When using the Backfill Method (trench) outdoors, what is the required application rate?
- 1.0 to 1.5 gallons per 10 square feet
- 2 gallons per 10 linear feet per foot of depth of the trench
- 1.0 gallon per 10 linear feet of trench
- 2 gallons per cubic foot of soil
Show answer
The label states the rate for the Backfill Method is 2 gallons per 10 linear feet per foot of depth of the trench.🔗 Source
Regarding air circulation systems, when should any system that moves air from the treated area to an untreated interior space be turned off?
- Only during the actual injection process
- Until application is complete and all finished dilution has been absorbed by the soil
- For 24 hours after the application is finished
- Only if the application is being done in SA-Mode
Show answer
The label requires turning off air circulation systems until application is completed and all finished dilution has been absorbed by the soil.🔗 Source
← All practice exams