Start practice — 8 questions →
Sample questions
Under which weather conditions should a technician avoid applying Apogee 123?
- Gusty wind conditions or temperature inversions
- High humidity or heavy rain
- Direct sunlight or high heat
- Low calcium or carbonate water levels
Show answer
The timing/weather section advises to avoid applications during gusty wind conditions and temperature inversions.🔗 Source
Which of the following is a restriction regarding the application method of Apogee 123?
- Do not apply through any type of irrigation system
- Do not apply during temperature inversions
- Do not apply in windy conditions
- Do not apply more than once per season
Show answer
The restrictions section explicitly states: 'DO NOT apply through any type of irrigation system.'🔗 Source
What is the maximum allowed application rate of Apogee 123 within any 21-day interval?
- 48 ozs/A (3 lbs)
- 99 ozs/A (6.2 lbs)
- 12 ozs/A
- 27.5 ozs/A
Show answer
The restrictions state: 'DO NOT apply more than 48 ozs/A (3 lbs) of Apogee within any 21-day interval.'🔗 Source
What is the primary purpose of using Apogee 123 according to the label?
- To control vegetative growth
- To eliminate fire blight in all apple varieties
- To increase calcium levels in soil
- To kill grass grown for seed
Show answer
The label describes Apogee 123 as a plant growth regulator used to control vegetative growth.🔗 Source
What is the Re-entry Interval (REI) for Apogee 123?
- 12 hours
- 21 days
- 48 hours
- 99 hours
Show answer
The label lists the rei_hours as 12.🔗 Source
When mixing Apogee 123, what should a technician do if the water source contains high calcium or carbonate?
- Use high quality spray grade ammonium sulfate (AMS)
- Mix with calcium or boron sprays to balance
- Increase the dilution rate significantly
- Avoid using the water source entirely
Show answer
The mixing notes state to use high quality spray grade ammonium sulfate (AMS) if the water source contains high calcium or carbonate.🔗 Source
In which of the following locations is fire blight management NOT registered for use on apples?
- California
- Peanut fields
- Sweet cherry orchards
- Grass seed areas
Show answer
The restrictions state: 'Fire blight management is not registered for use in California on apple.'🔗 Source
According to the PPE requirements, which material is acceptable for chemical-resistant gloves?
- Polyethylene or polyvinyl chloride
- Cotton or canvas
- Leather or suede
- Rubber or latex only
Show answer
The PPE section specifies chemical-resistant gloves made of waterproof material such as polyethylene or polyvinyl chloride.🔗 Source
← All practice exams